Select the icon to the right of the field for the project setting to open the project setting screen as shown below and enter in your IP address, TCP for protocol, the port number for the socket # you are using and the PLCs name you wrote down earlier.ġ3. Set the connection type to TCP/IP (call)ġ2. To Download the application > select Connection > select communication & OS. Select apply when finished and select esc 4 times to go back to the PLCs normal screen.ġ0. To change it select the row to highlight it and scroll up or down.

tcp ip view

Make sure the port number on the PLC matches the ones described for each socket number. Select Apply when finished and select Esc to go back one screen > Select Socket parameters > select the Socket 0 row for Socket to highlight it > scroll up or down until you get to the socket number you are using in your program. Select Esc 2 times to go back to the main menu > Select Ethernet > Select IP parameters and enter in the IP address, subnet mask and gateway of the parameters you are using in your program on Visilogic.ĩ. Select Version > select software and write down the PLC name to the controller currently stored on the PLC.Ĩ. The default password is 1111 and select the big return arrow button.ħ. Hold your finger anywhere on the screen for 10 seconds until you see an Info Mode screen appear. Power up the PLC if you haven't already done so. Set the client/server to Server(slave).Ħ. Connect a TCP/IP Socket Init FB to the Card Init to setup the socket number you will use, protocol is set to TCP, local port depends on the socket number, # 0 is 20000, # 1 is 20256, # 2 is 502, and # 3 is 20257.

tcp ip view

  • Add the function PLC name after TCP/IP card Init and configure your PLC name.ĥ.
  • tcp ip view

  • The PLC Name, TCP/IP Card Init and TCP/IP Socket Init can be found under the Com tab when selecting Main Module under the ladder row in the solution explore field to the left of the software screen.
  • In the ladder code add the function TCP/IP card Init after a direct contact of SB2 and configure the IP address, Subnet mask and default gateway according to your network settings.
  • The PLC must need to have or comprise an Ethernet card in one of the com ports on the controller.
  • To download to the PLC form your PC using an ethernet connection please follow the steps below:

    tcp ip view

    Connection over Ethernet with TCP/IP(call) using Visilogic